7
TP - SECTION 7 – MEMBRANE FLASHING
7.1
General
7.1.1
To ensure protection against water entry into a newly installed roofing system, membrane
flashing shall be installed at all membrane terminations as the application of the membrane
9
TP - SECTION 9 – PROTECTED MEMBRANE & COMBINATION
DESIGNS
9.1
General
9.1.1
A protected membrane roofing design is an insulated and ballasted roofing system in which
the insulation is applied above the thermoplastic membrane and retained in place by
10
TP - SECTION 10 – RE-ROOFING
10.1
General
10.1.1
Re‐roofing encompasses both membrane replacement and replacement in whole or in part
of the roof assembly above the structural deck for both un‐insulated and insulated roofing
systems including protected membrane designs.
11
TP - SECTION 11 – VEGETATIVE (GREEN) ROOFING
11.1
General
11.1.1
11.1.2
11.1.3
11.1.4
11.1.5
11.1.6
11.1.7
A vegetated roof design is defined as a roof membrane system with a top layer of living