ARCA logo

Flashing Details: Roof Edge With Low Parapet Wall

Roof Edge with Low Parapet Wall

Scope of Roofing by Roofer

vapour retardant

optional vapour retardant termination

2

primary insulation

3

secondary insulation

4

fibre cant strip

5

primary membrane and membrane protection

6

membrane flashing

7

metal base flashing

8

metal cap flashing

NOTE: Items 7 and 8 may be one piece.

Suggested Details by Others

a

accepted deck

b

air/vapour seal

c

sloped wood blocking